Using your
R
NAPCO
FREEDOM
F-TPG Garage Touchpad
Home Security System
© NAPCO 2005
PATENTED
OI309 10/05
1
TABLE OF CONTENTS
TABLE OF CONTENTS
INTRODUCTION ..............................................................................2
TESTING THE SYSTEM ..................................................................2
GARAGE TOUCHPAD INDICATORS ..............................................4
GARAGE TOUCHPAD CONTROLS ................................................5
ARMING WHEN LEAVING...............................................................6
BYPASSING FAULTED ZONES ......................................................7
ARMING WHEN STAYING HOME ...................................................8
ARMING AND LEAVING WITH OTHERS STAYING........................9
EXITING WITH THE SYSTEM ALREADY ARMED .........................10
EMERGENCY BUTTONS.................................................................12
DISARMING THE SYSTEM..............................................................13
SILENCING AN ALARM ...................................................................14
FIRE PROTECTION .........................................................................15
SYSTEM TROUBLE ERROR CODES..............................................17
ZONE LIST .......................................................................................19
ENROLLING A NEW F-IFOB............................................................20
LOST GARAGE DOOR OPENER MODE.........................................21
FCC PART 68 STATEMENT ...........................................................22
LIMITATIONS OF THIS ALARM SYSTEM .......................................23
LIMITED WARRANTY ......................................................................25
FCC PART 15 STATEMENT ............................................................27
R
IF THE ALARM IS SOUNDING:
To silence an alarm, in-
sert your F-IFOB key into
the slot on the Touchpad
and remove when alarm
has silenced. Proceed
with caution!
pages 14 & 15).
(See
ALARM TIME OUT: _________ Minutes
FOR SERVICE, CALL: _____________________
TO CANCEL AN
ALARM REPORT, CALL: ____________________
3
GARAGE TOUCHPAD INDICATORS
The green READY light shows the status of the zones in your system:
ON indicates that all zones are secure and the system is ready to be armed.
FLASHING indicates that at least one zone is open. To determine the open zone, count the
number of flashes and refer to the zone list on your security panel.
OFF indicates that the optional second deadbolt is not locked. If there are two deadbolts in
the system, the other deadbolt must be locked before the system can be armed.
The red ARMED light ON indicates that the system is armed.
READY
ARMED
STAY
BLINKING with the siren sounding indicates that the system is in alarm.
BLINKING with no siren indicates Alarm Memory (the alarm has been silenced or timed
out). To determine the zone in alarm, count the number of flashes and refer to the zone list
on your security panel. Press SILENCE to clear the alarm memory. (see page 13)
The yellow STAY light ON indicates that the system is armed in the STAY mode, allowing
free movement throughout the premises, while maintaining perimeter protection.
FIRE
TBL
The red FIRE light will flash to indicate that the system is in a Fire Alarm Condition*. If a fire
is in progress, evacuate the premises immediately!
* Note: This feature may not apply to your system. Consult your installer to determine if your system includes fire protection.
•
The yellow trouble TBL light will light and the Touchpad sounder will pulse to indicate that a
system trouble is present. If zone(s) have been bypassed, TBL will light steadily. (See
SYSTEM TROUBLE ERROR CODES, Page 17).
The green AC Light ON indicates that AC Power is present.
4
GARAGE TOUCHPAD CONTROLS
STAY Button - Press to arm system in the STAY mode. Perimeter devices such as windows and doors will
be protected, while interior protective devices such as motion sensors will be de-activated, allowing free
movement throughout the premises.
AWAY Button - Press to arm system in AWAY mode when no one is to remain home. System will be fully
armed with all perimeter and interior devices activated.
BYPASS Button - This button has multiple functions, depending on the state of the panel.
BYPASS - If you are attempting to arm the system with open zones that cannot be immediately repaired, press BYPASS to tempo-
rarily remove these zones from the system. The Touchpad will beep and trouble TBL will light steady. Press STAY or AWAY to arm
the system as usual (see page 7).
TEST - To test the system, hold down the BYPASS button for 4 seconds to generate a test report to central station and chirp the siren.
If the test fails, the Touchpad will beep and the trouble light (TBL) will flash. Hold down BYPASS for 8 seconds to do a “system walk
test” of your protective devices. Press SILENCE to reset. (See page 2).
SILENCE Button - Press to silence a Fire Alarm* (page 15), silence system troubles and view system trou-
bles (page 17). * Note: This feature may not apply to your system. Consult your installer to determine if your system in-
cludes fire protection.
Hold down for 4 seconds to remove F-IFOBs from the System - See page 20.
EMERGENCY BUTTONS
Press to alert Central Station of a Police Emergency.
Press to alert Central Station of a Fire Emergency.
Press to alert Central Station of an Auxiliary Emergency.
POLICE EMERGENCY
FIRE EMERGENCY
AUXILIARY EMERGENCY
SIREN - Will sound a LOUD steady sweep tone when intrusion is detected or a distinct pulsating tone for a
fire alarm condition.
MOTION SENSOR - Detects movement in the premises. Do NOT block.
F-IFOB - The F-IFOB is a uniquely coded digital key which must be used to disarm the system and silence the siren in case
of alarm. To silence an alarm, simply insert into the F-IFOB slot on the Touchpad and remove when alarm has silenced.
5
ARMING WHEN LEAVING
If you are leaving with NO other family members remaining home:
Check the Garage Touchpad indicators. The green READY light should be ON-STEADY, indicating
that the system is ready to arm.
READY
1
2
•
If the green READY light is BLINKING, this indicates that a zone is faulted. The READY light is blinking out the zone
number of the open zone. Count the flashes and look at your zone list to see which zone is open and secure it (close
the door or window, etc.). If you cannot immediately secure the zone, it may be bypassed (see page 7).
•
If the green READY light is OFF, the optional second deadbolt is not locked. If there are two deadbolts in the system,
the other deadbolt must be locked before the system can be armed. Go to the other deadbolt location and lock it.
Press the AWAY button on the Touchpad.
ꢀ If you change your mind after pressing AWAY, press SILENCE to clear arming.
The ARMED indicator will begin to flash, indicating that you have up to 3 minutes to exit through the
ARMED
garage and close the door.
Open the garage door and exit within 3 minutes. (Note: See page 13 if your garage door motor fails).
3
4
When the garage door closes (either by pressing A1 or A2 on your Keyfob or with your standard garage
door opener remote control), the Garage Touchpad will give one chirp to indicate the system has armed.
ꢀ If the garage door has not been closed within 3 minutes of pressing AWAY, the system will revert
back to a disarmed state.
ꢀ If the system detects movement inside the premises within 3 minutes of arming, it will automati-
cally revert to Stay mode, providing perimeter protection with the interior protection (motion sen-
sors) turned off. (See ARMINGWHENSTAYINGHOME - page 8).
6
BYPASSING FAULTED ZONES
If you are trying to arm with a faulted zone or zones, the green READY light will be blinking out the number of the faulted
zones. If you cannot repair the zone(s), they may be temporarily removed from the system, or bypassed, using the fol-
lowing procedure:
Press the BYPASS button.
1
The Garage Touchpad will beep and the yellow Trouble indicator will light ON STEADY.
TBL
Press either the STAY or AWAY button.
2
If arming AWAY, open the garage door and exit. (Note: See page 13 if your garage door mo-
tor fails).
3
4
The system will arm with the faulted zones bypassed.
When the garage door closes, the Garage Touchpad will give one chirp to indicate the system has
armed.
Warning: Bypassed zones are unprotected. If a faulted zone cannot be secured, have the
system checked as soon as possible.
7
ARMING WHEN STAYING HOME
Arming in the Stay mode allows you to remain home with the perimeter protection active and the interior protection off, so
that you may move freely about the premises.
Check the Garage Touchpad indicators. The green READY light should be ON-STEADY, indicating
that the system is ready to arm.
READY
1
•
If the green READY light is BLINKING, this indicates that a zone is faulted. The READY light is blinking out the zone
number of the open zone. Count the flashes and look at your zone list to see which zone is open and secure it (close
the door or window, etc.). If you cannot immediately secure the zone, it may be bypassed (see page 7).
•
If the green READY light is OFF, the optional second deadbolt is not locked. If there are two deadbolts in the system, the
other deadbolt must be locked before the system can be armed. Go to the other deadbolt location and lock it.
Press the STAY button on the Touchpad.
2
3
If the garage door is already closed, the ARMED indicator will light and STAY will begin to flash. The
system will arm in the Stay mode within 3 minutes.
ARMED
STAY
If the garage door is NOT closed, close the garage door from the inside to arm the system.
ꢀ If the garage door has not been closed within 3 minutes of pressing STAY, the system will re-
vert back to a disarmed state. (Note: See page 13 if your garage door motor fails).
The STAY indicator will stop flashing and light steady, indicating the system is armed in the Stay mode.
STAY
8
ARMING AND LEAVING WITH OTHERS STAYING
If you are arming and leaving with other family members remaining home:
Check the Garage Touchpad indicators. The green READY light should be ON-STEADY,
READY
indicating that the system is ready to arm.
1
•
If the green READY light is BLINKING, this indicates that a zone is faulted. The READY light is blinking out the zone
number of the open zone. Count the flashes and look at your zone list to see which zone is open and secure it
(close the door or window, etc.). If you cannot immediately secure the zone, it may be bypassed (see page 7).
•
If the green READY light is OFF, the optional second deadbolt is not locked. If there are two deadbolts in the system,
the other deadbolt must be locked before the system can be armed. Go to the other deadbolt location and lock it.
Press the STAY button on the Touchpad.
2
STAY will begin to flash, indicating the 3 minute exit delay period.
STAY
Open the garage door and exit. (Note: See page 13 if your garage door motor fails).
3
4
Close the garage door from the outside to arm the system (either by pressing A1 or A2 on your
Keyfob or with your existing garage door opener remote control).
ꢀ If the garage door has not been closed within 3 minutes of pressing STAY, the system will
revert back to a disarmed state.
9
EXITING WITH THE SYSTEM ALREADY ARMED
If the system is Armed STAY and you are leaving with other family members remaining home:
Press the STAY button on the Touchpad.
1
The ARMED indicator will light and STAY will begin to flash, indicating that you have up to 3
minutes to exit through the garage and close the door.
ARMED
STAY
Open the garage door from the inside. System will disarm.
2
Exit the garage.
3
Close the garage door from the outside to arm the system (either by pressing A1 or A2 on your
Keyfob or with your existing garage door opener remote control).
4
ꢀ If the garage door has not been closed within 3 minutes of pressing STAY, the system will
revert back to a disarmed state.
(Note: See page 13 if your garage door motor fails).
10
EXITING WITH THE SYSTEM ALREADY ARMED
If the system is Armed STAY and you are leaving with NO other family members remaining home:
Press the AWAY button on the Touchpad.
1
The ARMED indicator will begin to flash, indicating that you have up to 3 minutes to exit through the
ARMED
garage and close the door.
Open the garage door from the inside. System will disarm.
2
3
4
Exit the garage.
Close the garage door from the outside (either by pressing A1 or A2 on your Keyfob or with your exist-
ing garage door opener remote control) to arm the system. The Garage Touchpad will give one chirp to
indicate the system has armed.
ꢀ If the garage door has not been closed within 3 minutes of pressing AWAY, the system will re-
vert back to a disarmed state.
ꢀ If the system detects movement inside the premises within 3 minutes of arming, it will automati-
cally revert to Armed STAY mode, providing perimeter protection with the interior protection
(motion sensors) turned off. (See ARMINGWHEN STAYING HOME - page 8). (Note: See page
13 if your garage door motor fails).
11
EMERGENCY BUTTONS
Emergency Buttons (Only available if programmed).
The Emergency Buttons, if programmed, are always active, whether the system is armed
or disarmed. The Emergency Button must be Held Down for 3 seconds to activate the
emergency alarm and transmit the signals to central station.
Police Emergency Hold down the Police Emergency button to alert the central station of
a police emergency. * (Police Emergency programmed? YES NO)
Fire Emergency Hold down the Fire button to alert the central station of a fire
emergency. * (Fire Emergency programmed? YES NO)
Auxiliary Emergency Hold down this button to alert the central station of an auxiliary
emergency. * (Auxiliary Emergency programmed? YES NO)
Auxiliary Emergency: _______________________________________
12
DISARMING THE SYSTEM
DISARMING WHEN RETURNING HOME:
When returning home, opening your garage door (by pressing A1 or A2 on your Keyfob) from the outside will
automatically disarm the system. The red ARMED light will go out and the green READY light will turn on.
If an alarm has occurred while you were away, the red ARMED light will be flashing and the F-TPG Touchpad
sounder will be active. Proceed with caution! If you suspect that an intruder may still be in the premises, leave
immediately and call authorities from a neighbor's telephone.
DISARMING WHEN HOME (ARMED STAY):
When home with the system armed in the Stay mode, opening the garage door from the inside will disarm the
system*. The red ARMED light and yellow STAY will go out and the green READY light will turn on.
*If you have an inside door protected by the Freedom system, you can unlock the deadbolt on this door to disarm
the system instead of opening the outside garage door.
The system may always be disarmed with the F-IFOB. To disarm the system, insert your F-IFOB key into the
IFOB slot on the Garage Touchpad and remove when the system is disarmed.
GARAGE DOOR MOTOR FAILURE
In the event your garage door motor fails, the procedure for arming the system does not change (except of course
that your garage door will need to be opened and closed manually). However, to DISARM the system without the
garage door motor, you MUST use the F-IFOB to disarm within 30 seconds of manually opening the out-
side garage door.
13
SILENCING AN ALARM
If an alarm occurs while you are at home:
The Garage Touchpad siren will sound and the red ARMED light will flash.
Proceed with caution! If you suspect that an intruder may still be in the premises, leave
immediately and call authorities from a neighbor's telephone.
ARMED
ARMED
To silence the alarm, insert your F-IFOB key into the IFOB slot on the Garage Touchpad and re-
move when alarm has silenced.
The red ARMED light will continue to flash the number of the zone(s) on which the alarm occurred.
Determine which zone caused the alarm and then press SILENCE to clear the alarm memory.
If an alarm occurs while you are away:
When you unlock the deadbolt to enter, the Garage Touchpad sounder will activate and the red
ARMED
ARMED light will be flashing to warn you that an alarm had occurred while you were away.
Proceed with caution! If you suspect that an intruder may still be on the premises, leave
immediately and call authorities from a neighbor's phone.
To disarm the system, you must insert your F-IFOB key into the F-IFOB slot on the Garage Touch-
pad. If the system is not disarmed in 30 seconds, the alarm will sound.
The red ARMED light will continue to flash the number of the zone(s) on which the alarm occurred.
Determine which zone caused the alarm and then press SILENCE to clear the alarm memory.
ARMED
14
FIRE PROTECTION*
If a fire is detected, the siren will sound a distinct pulsating tone and the FIRE indicator on the Ga-
rage Touchpad will be flashing. If a Fire Alarm does occur:
FIRE
* Note: This feature may not apply to your system. Consult your installer to determine if your system includes fire protection.
If a fire is in progress, evacuate the premises immediately! Call the Fire Department from an outside phone.
1
2
If there is no evidence of a fire, press SILENCE OR insert your F-IFOB key into the Garage Touchpad.
The siren will silence, and FIRE on the Garage Touchpad will stop flashing, and light steady.
Determine which device went into alarm. If you are protected by smoke detectors, the light on the
active detector will be lit. Once it is determined which smoke detector is in alarm, press SILENCE to
reset the smoke detector.
3
4
If the Fire Zone has reset properly, the FIRE light should go out in approximately 30 seconds. If it
does not go out, press SILENCE again in a few minutes. If it still does not go out, call for service.
FIRE
Fire-Zone Trouble
The system is constantly monitoring the Fire Zone to insure the connections to the protective de-
vices are in good working order.
• If a problem on a Fire Zone is detected, a System Trouble will display. The sounder will activate
and the Trouble TBL light will blink 7 times.
TBL
Press the SILENCE button to silence the sounder. Call for service immediately.
15
FIRE PROTECTION
3. Each person tests his door.
4. Pretend the door is hot and use
the alternate escape exit.
5. Everyone meets outdoors at
the assigned location.
your shoulder against it and open
it cautiously. Be ready to slam the
door if smoke or heat rushes in.
Crawl through smoke, holding your
breath. Close the doors again on
leaving to help prevent the fire
from spreading.
Preparing a Fire Escape Plan
Even with the most advanced fire
alarm system, adequate protection
requires an escape plan.
To prepare your plan, draw floor
plans of your building. Show two
exits - a front or back door and a
window from each room. (Make sure
the window works. You may need a
special fire-escape ladder if the
window is high up). Write down your
outside meeting place.
Important! - Read Carefully
Discuss these escape procedures
with all those who use the building:
1. In a residence, sleep with the
bedroom door closed. A closed
door will hold back deadly smoke
while you escape.
2. When the fire alarm signals,
escape quickly. Do not stop to
pack.
4. Go to your specific outdoor
meeting place so you can see that
everyone is safe.
5. Assign someone to make sure
nobody returns to the burning
building.
6. Call the Fire Department from a
neighbor's telephone.
Family Rehearsal
Rehearse each of the following
activities:
3. Test the door. If it is hot, use your
alternate route through the
window. If the door is cool, brace
1. Everyone in his room with the
doors closed.
2. One person sounds the alarm.
Would You Like More Safety Information?
For more information on home fire detection, burn safety, and home fire safety, write to the National Fire Protection
Association, Public Affairs Dept. 05A, Batterymarch Plaza, Quincy, MA 02269.
16
SYSTEM TROUBLE ERROR CODES
Your Freedom Alarm System is constantly monitoring its own components, as well as all critical services, such as AC power and the
telephone line, to insure that it is always ready to provide the protection for which it was designed. When a system trouble occurs, the
Garage Touchpad will caution you with a Trouble TBL light and a beeping sounder.
If you cannot immediately fix the trouble, the system can still be used. Simply press SILENCE to view the trouble as described below
and press SILENCE again to exit the VIEW TROUBLE mode. The system can now be armed.
To view the trouble, press SILENCE, count the number of Trouble TBL and READY flashes and refer to the following table. If there
is more than one trouble to view, press SILENCE again to scroll to the next trouble, and again to exit the VIEW TROUBLE mode. The
Trouble TBL light will remain pulsing as a reminder if the trouble is still present. NOTE: If the Touchpad siren chirps once every 10 sec-
onds, call for service.
READY
Flashes
TBL Flashes /
Touchpad beeps
Trouble Condition
Action
STEADY
NONE Zones Bypassed
This is a reminder that zones have been bypassed (by pressing BYPASS). If it is
necessary to bypass any inoperative zones, it is important to have the zones re-
paired as soon as possible.
1
NONE AC Power Failure
NONE Low Battery
This trouble will occur if AC power is not present. Make sure the system trans-
former is plugged into its AC receptacle and check the circuit breaker, otherwise
call for service.
2
3
If there has been a recent power failure, the battery may be partially depleted and
must be recharged by the control panel. If the trouble does not clear in 24 hours,
call for service.
The system was not able to report to central station. If this is due to a temporary
interruption in the telephone service, the trouble can be cleared when the service
is restored by pressing SILENCE again.
NONE Communication
Failure
4
5
NONE Telephone Line Cut
NONE Bell/Siren Trouble
The telephone line has failed. If telephone service has been temporarily inter-
rupted, the trouble will clear when restored. Otherwise, call for service.
There is a problem with the Bell or Siren. Call for service.
17
SYSTEM TROUBLE ERROR CODES
READY
Flashes
TBL Flashes /
Touchpad beeps
6
Trouble Condition
Action
NONE Lost Key Mode
This is a reminder that the system has been put into the lost key mode ([STAY] &
[AWAY] pressed simultaneously). While in this mode, the system can only be
disarmed with your F-IFOB. When you have replaced or re-keyed your garage
door opener, press [STAY] & [AWAY] simultaneously again to exit lost key mode.
A problem has been detected with the Fire zone. Call for service.
7
1
NONE Fire Zone Trouble
1
Wireless Receiver TBL A problem has been detected with the wireless receiver. Call for service.
or Touchpad TBL
2
3
2
Wireless Receiver Jam A problem has been detected with a wireless receiver. Call for service.
1-8
Wireless Transmitter
Low Battery
The battery in a wireless transmitter is low and should be replaced. This transmit-
ter is on the zone corresponding to the number of READY flashes. The replace-
ment battery for the GEM-TRANS2 door/window transmitter, GEM-PIR motion
detector and GEM-GB glass break detector is the Duracell DL123A 3 Volt Lithium
(2 required for the GEM-PIR and GEM-GB). The GEM-DT Dual Technology Sen-
sor requires 4 C cell Alkaline batteries. Warning: Replace batteries only with the same
type as specified above. Use of another battery may present a risk of fire or explosion. Do
not recharge or disassemble battery, or dispose of in fire.
4
5
1-8
1-4
Wireless Transmitter
Supervisory Failure
A problem has been detected with a wireless transmitter on the zone correspond-
ing to the number of READY flashes. Call for service.
Wireless Smoke
Detector Low Battery
The battery in a wireless smoke detector is low and should be replaced. The
number of the smoke detector corresponds to the number READY flashes. The
replacement battery is the Duracell MN1604 9 Volt Alkaline (2 required).
Warning: Replace batteries only with the same type as specified above. Use of another
battery may present a risk of fire or explosion. Do not recharge, disassemble, or dispose of
battery in a fire.
6
1-4
Wireless Smoke
Detector Supervisory
Failure
A problem has been detected with a wireless smoke detector. Call for service.
18
ZONE LIST
The space below is for recording the descriptions of the zones in your system.
•
If the system has a faulted zone, count the number of READY light flashes and refer to the list below to see which
zone is open and secure it (close the door or window, etc.).
•
If an alarm has occurred, count the number of ARMED light flashes and refer to the list below to see which zone
caused the alarm:
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 5
ZONE 6
ZONE 7
ZONE 8
19
ENROLLING A NEW F-IFOB
The F-IFOB is a uniquely coded digital key which performs the following functions when inserted into the F-IFOB slot on the Ga-
rage Touchpad:
• Disarm an armed system
• Silence an active alarm
• Reset a fire alarm
The Master F-IFOB supplied with your system will perform all of these functions, plus it may also be used to add up to 5 addi-
tional F-IFOBs to the system. The following instructions will guide you through adding additional F-IFOBs as well as removing
F-IFOBs in the event that one is lost.
Adding additional IFOBs to your system:
1. With the system disarmed, insert the Master F-IFOB into the F-IFOB slot on the Garage Touchpad.
2. Wait for beep and then remove the Master F-IFOB.
3. Within 8 seconds insert the new F-IFOB into the F-IFOB slot on the Garage Touchpad.
4. Wait for 5 beeps and remove the new F-IFOB.
5. Test the new F-IFOB by arming the system in the STAY mode and using the F-IFOB to disarm
the system.
Repeat the above steps for each F-IFOB to be enrolled.
Removing IFOBs from the system:
In the event that an F-IFOB is lost, the following procedure must be used to remove all of the F-IFOBs
except the Master:
On a disarmed system:
1. Insert the Master F-IFOB, until beep.
2. Hold Down the SILENCE button for 4 seconds, until beep.
Re-Enroll the F-IFOBs using the procedure above.
In the event that the Master F-IFOB is lost, contact the alarm company to arrange a replacement.
20
LOST GARAGE DOOR OPENER MODE
Lost Opener Mode
In the event that your garage door remote control (or key that operates your garage door
opener) is lost or stolen, the system may still be used by arming in the Lost Garage Door
Opener Mode. In Lost Garage Door Opener Mode, the system may be armed as usual, how-
ever opening the garage door will not disarm the system. The system may only be disarmed
with the F-IFOB digital key.
Simultaneously hold down the STAY and AWAY buttons for 4 seconds to put the system in
the Lost Garage Door Opener Mode. The Trouble TBL light will begin to pulse. The system
may now be armed as usual, however, it may only be disarmed with your F-IFOB. To confirm
system is in Lost Garage Door Opener Mode, press SILENCE. The TBL light will pulse 6
times. Press SILENCE again to stop display Trouble.
When arriving home to an armed system, open your garage door. The Garage Touchpad
sounder will sound to remind you to disarm the system. You must insert the F-IFOB into the
F-IFOB slot to disarm the system within 30 seconds, or the alarm will sound.
NOTE: If you use a key-switch that operates your garage door opener, and this key is lost, it is
important that you have your locksmith re-key the lock, or have the lock switch replaced as
soon as possible. In addition, we strongly recommend keeping your F-IFOB on a different key
ring as this key-switch key. Similarly, if your garage door remote control is lost or stolen, be
sure that the wireless code is disabled or changed.
To exit Lost Garage Door Opener Mode and return to normal operation, simultaneously hold
down the STAY and AWAY buttons for 4 seconds. The TBL light will stop flashing.
21
FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68 STATEMENT
This equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is a label that contains, among
other information, the FCC registration number and ringer equivalence number (REN) for this equipment. If requested, this infor-
mation must be provided to the telephone company.
This equipment uses the following jacks: An RJ31 X is used to connect this equipment to the telephone network.
The REN is used to determine the quantity of devices which may be connected to the telephone line. Excessive IRENs on the
telephone line may result in the devices not ringing in response to an incoming call, in most, but not all areas, the sum of the
RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to the line, as determined by
the total RENs, contact the telephone company to determine the maximum REN for the calling area.
If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary dis-
continuance of service may be required. If advance notice is not practical, the telephone company will notify the customer as
soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe necessary.
The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation
of the equipment. If this happens, the telephone company will provide advance notice in order for you to make the necessary
modifications in order to maintain uninterrupted service.
If trouble is experienced with this equipment, please contact the manufacturer for repair and warranty information. If the trouble
is causing harm to the telephone network, the telephone company may request you remove the equipment from the network
until the problem is resolved.
There are no user serviceable components in this product, and all necessary repairs must be made by the manufacturer.
Other repair methods may invalidate the FCC registration on this product.
This equipment cannot be used on telephone company-provided coin service. Connection to Party Line Service is subject to
state tariffs.
This equipment is hearing-aid compatible.
When programming or making test calls to an emergency number, briefly explain to the dispatcher the reason for the call. Per-
form such activities in the off-peak hours; such as early morning or late evening.
22
WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM
While this system is an advanced design security system, it does not offer guaranteed protection against burglary or fire or other
emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variety of
reasons. For example:
• Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm sensor or
disconnect an alarm warning device.
• Intrusion detectors (e.g. passive infrared detectors), smoke detectors, and many other sensing devices will not work without
power. Battery operated devices will not work without batteries, with dead batteries, or if the batteries are not put in properly.
Devices powered solely by AC will not work if their AC power supply is cut off for any reason, however briefly.
• Signals sent by wireless transmitters may be blocked or reflected by metal before they reach the alarm receiver. Even if the
signal path has been recently checked during a weekly test, blockage can occur if a metal object is moved into the path.
• A user may not be able to reach a panic or emergency button quickly enough.
• Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation
manual. Passive Infrared Detectors do not provide volumetric area protection. They do create multiple beams of protection,
and intrusion can only be detected in unobstructed areas covered by those beams. They cannot detect motion or intrusion
that takes place behind walls, ceilings, floors, closed doors, glass partitions, glass doors, or windows. Mechanical tampering,
masking, painting or spraying of any material on the mirrors, windows or any part of the optical system can reduce their de-
tection ability. Passive Infrared Detectors sense changes in temperature; however, as the ambient temperature of protected
area approaches the temperature range of 90° to 105°F (32° to 40°C), the detection performance can decrease.
• Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers if they are located on the
other side of closed or partly open doors. If warning devices sound on a different level of the premises, then they are less
likely to alert all people. Persons may not hear the warning if the alarm is muffled from a stereo, radio, air conditioner or other
appliance, or by passing traffic. Finally, alarm warning devices, however loud, may not warn hearing-impaired people.
• Telephone lines needed to transmit alarm signals from a premises to an alarm monitoring center may be out of service
or temporarily out of service. Telephone lines are also subject to compromise by sophisticated intruders.
- Continued over
23
WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM (Continued)
• Even if the system responds to the emergency as intended, however, occupants may have insufficient time to protect them-
selves from the situation. In the case of a monitored alarm system, authorities may not respond appropriately.
• This equipment, like other electrical devices, is subject to component failure. Even though this equipment is designed to last
as long as 10 years, the electronic components could fail at any time.
The most common cause of an alarm system not functioning when an intrusion occurs is inadequate maintenance. This alarm
system should be tested weekly to make sure all sensors and transmitters are working properly.
Wireless transmitters (used with some systems) are designed to provide long battery life under normal operating conditions.
Longevity of batteries may be as much as 4 to 7 years, depending on the environment, usage, and the specific wireless device
being used. External factors such as humidity, high or low temperatures, as well as large swings in temperature, may all reduce
the actual battery life in a given installation. This wireless system, however, can identify a true low battery situation, thus allow-
ing time to arrange a change of battery to maintain protection for that given point within the system.
Installing an alarm system may make one eligible for lower insurance rates, but an alarm system is not a substitute for insur-
ance. Business owners, property owners and renters should continue to act prudently in protecting themselves and continue to
insure their lives and property.
We continue to develop new and improved protection devices. Users of alarm systems owe it to themselves and their employ-
ees to learn about these developments.
24
NAPCO LIMITED WARRANTY
NAPCO SECURITY SYSTEMS, INC. (NAPCO) warrants its products to be free from manufacturing defects in materials and
workmanship for thirty-six months following the date of manufacture. NAPCO will, within said period, at its option, repair or
replace any product failing to operate correctly without charge to the original purchaser or user.
This warranty shall not apply to any equipment, or any part thereof, which has been repaired by others, improperly installed,
improperly used, abused, altered, damaged, subjected to acts of God, or on which any serial numbers have been altered,
defaced or removed. Seller will not be responsible for any dismantling or reinstallation charges.
THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE
HEREOF. THERE IS NO EXPRESS OR IMPLIED WARRANTY OF MERCHANTABILITY OR A WARRANTY OF FITNESS
FOR A PARTICULAR PURPOSE. ADDITIONALLY, THIS WARRANTY IS IN LIEU OF ALL OTHER OBLIGATIONS OR
LIABILITIES ON THE PART OF NAPCO.
Any action for breach of warranty, including but not limited to any implied warranty of merchantability, must be brought within the
six months following the end of the warranty period.
IN NO CASE SHALL NAPCO BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR
BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, EVEN IF THE LOSS OR DAMAGE IS CAUSED
BY THE SELLER'S OWN NEGLIGENCE OR FAULT.
In case of defect, contact the security professional who installed and maintains your security system. In order to exercise the
warranty, the product must be returned by the security professional, shipping costs prepaid and insured to NAPCO. After repair
or replacement, NAPCO assumes the cost of returning products under warranty. NAPCO shall have no obligation under this
warranty, or otherwise, if the product has been repaired by others, improperly installed, improperly used, abused, altered,
damaged, subjected to accident, nuisance, flood, fire or acts of God, or on which any serial numbers have been altered,
defaced or removed. NAPCO will not be responsible for any dismantling, reassembly or reinstallation charges.
This warranty contains the entire warranty. It is the sole warranty and any prior agreements or representations, whether oral or
25
written, are either merged herein or are expressly cancelled. NAPCO neither assumes, nor authorizes any other person
purporting to act on its behalf to modify, to change, or to assume for it, any other warranty or liability concerning its products.
In no event shall NAPCO be liable for an amount in excess of NAPCO's original selling price of the product, for any loss or
damage, whether direct, indirect, incidental, consequential, or otherwise arising out of any failure of the product. Seller's
warranty, as hereinabove set forth, shall not be enlarged, diminished or affected by and no obligation or liability shall arise or
grow out of Seller's rendering of technical advice or service in connection with Buyer's order of the goods furnished hereunder.
NAPCO RECOMMENDS THAT THE ENTIRE SYSTEM BE COMPLETELY TESTED WEEKLY.
Warning: Despite frequent testing, and due to, but not limited to, any or all of the following; criminal tampering, electrical or
communications disruption, it is possible for the system to fail to perform as expected. NAPCO does not represent that the
product/system may not be compromised or circumvented; or that the product or system will prevent any personal injury or
property loss by burglary, robbery, fire or otherwise; nor that the product or system will in all cases provide adequate warning or
protection. A properly installed and maintained alarm may only reduce risk of burglary, robbery, fire or otherwise but it is not
insurance or a guarantee that these events will not occur. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY
PERSONAL INJURY, PROPERTY DAMAGE, OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE
WARNING. Therefore, the installer should in turn advise the consumer to take any and all precautions for his or her safety
including, but not limited to, fleeing the premises and calling police or fire department, in order to mitigate the possibilities of
harm and/or damage.
NAPCO is not an insurer of either the property or safety of the user's family or employees, and limits its liability for any loss or
damage including incidental or consequential damages to NAPCO's original selling price of the product regardless of the cause
of such loss or damage.
Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusion or limitation of
incidental or consequential damages, or differentiate in their treatment of limitations of liability for ordinary or gross negligence,
so the above limitations or exclusions may not apply to you. This Warranty gives you specific legal rights and you may also
have other rights which vary from state to state.
26
THE FOLLOWING STATEMENT IS REQUIRED BY THE FCC
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits for a Class-B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio-frequency energy and, if not installed and used in accordance with the instruc-
tions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
• Reorient or relocate the receiving antenna;
• Increase the separation between the equipment and the receiver;
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected;
• Consult the dealer or an experienced radio/TV technician for help.
You may also find the helpful the following booklet, prepared by the FCC: “How to Identify and Resolve Radio-TV Interference
Problems”. This booklet is available from the U.S. Government Printing Office, Washington, DC 20402.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority
to operate this equipment under Federal Communications Commissions rules.
This device complies with part 15 of FCC Rules. Operation is subject to the following two conditions; (1) This device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
This Class B digital apparatus complies with Canadian ICES-003 Cet appareil numérique de la classe B est conforme à la
norme NMB-003 du Canada.
27
333 Bayview Avenue
Amityville, New York 11701
For Sales and Repairs, (800) 645-9445
For Technical Service, (800) 645-9440
R
Publicly traded on NASDAQ
Symbol: NSSC
© NAPCO 2005
28
|